Thiết kế hệ thống chiếu sáng phòng khách

Height of Room: 3.500 m, Maintenance factor: 0.80 Values in Lux, Scale 1:143

Surface  [%] Eav [lx] Emin [lx] Emax [lx] u0

Workplane / 228 55 737 0.243

Floor 63 207 28 550 0.135

Ceiling 70 104 55 132 0.533

Walls (4) 70 100 14 220 /

Workplane:

Height: 1.000 m

Grid: 64 x 16 Points

Boundary Zone: 0.500 m

Illuminance Quotient (according to LG7): Walls / Working Plane: 0.271, Ceiling / Working Plane: 0.456.

Pure daylight scene, no luminaires involved.

pdf14 trang | Chuyên mục: Hệ Thống Điện | Chia sẻ: yen2110 | Lượt xem: 482 | Lượt tải: 0download
Tóm tắt nội dung Thiết kế hệ thống chiếu sáng phòng khách, để xem tài liệu hoàn chỉnh bạn click vào nút "TẢI VỀ" ở trên
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / 3D Rendering
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 1 / Summary
Height of Room: 3.500 m, Maintenance factor: 0.80 Values in Lux, Scale 1:143
Surface  [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 228 55 737 0.243
Floor 63 207 28 550 0.135
Ceiling 70 104 55 132 0.533
Walls (4) 70 100 14 220 /
Workplane:
Height: 1.000 m
Grid: 64 x 16 Points 
Boundary Zone: 0.500 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.271, Ceiling / Working Plane: 0.456. 
Pure daylight scene, no luminaires involved.
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 1 / Workplane / Isolines (E)
Values in Lux, Scale 1 : 143
Position of surface in room:
Working plane with 0.500 m 
Boundary Zone
Marked point:
(0.500 m, 0.500 m, 1.000 m) 
Grid: 64 x 16 Points 
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
228 55 737 0.243 0.075
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 1 / Workplane / Greyscale (E)
Scale 1 : 143
Position of surface in room:
Working plane with 0.500 m 
Boundary Zone
Marked point:
(0.500 m, 0.500 m, 1.000 m) 
Grid: 64 x 16 Points 
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
228 55 737 0.243 0.075
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 7 / Photometric Results
Total Luminous Flux: 0 lm
Total Load: 0.0 W
Maintenance factor: 0.80
Boundary Zone: 0.500 m
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²] 
direct indirect total
Workplane 336 139 475 / / 
Floor 297 135 431 63 86
Ceiling 0.00 217 217 70 48
Wall 1 55 165 220 70 49
Wall 2 71 154 225 70 50
Wall 3 40 184 224 70 50
Wall 4 9.25 96 105 70 23
Uniformity on the working plane
u0: 0.243 (1:4) 
Emin / Emax: 0.075 (1:13) 
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.271, Ceiling / Working Plane: 0.456. 
Specific connected load: 0.00 W/m² = 0.00 W/m²/ lx (Ground area: 120.00 m²) 
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 1 / Workplane / Value Chart (E)
Values in Lux, Scale 1 : 143
Not all calculated values could be displayed. 
Position of surface in room:
Working plane with 0.500 m 
Boundary Zone
Marked point:
(0.500 m, 0.500 m, 1.000 m) 
Grid: 64 x 16 Points 
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
228 55 737 0.243 0.075
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
HavellsSylvania 0058834 EQUILIBRO MPD 2x55W A2 / Luminaire Data Sheet
Luminous emittance 1: 
Luminaire classification according to CIE: 100
CIE flux code: 46 79 96 100 45
EQUILIBRO represents a new concept in lighting, ideally suited to the 
exacting demands of the modern workplace. The range combines compact 
fluorescent lamps benefits with a unique reflector system in a variety of 
stylish, harmonious bodies, to provide a comfortable and original lighting 
solution. 
Description : 
Recessed fixture 600 x 600 module with body made of white polyester/epoxy 
powder painted steel and polycarbonate opal diffuser inset in white metal 
screen painted in polyester/epoxy powderl for compact fluorescent lamps 
36W-L or 55W-LE. 
Applications : 
Tertiary or commercial sector: open-plan offices, executive offices, meeting 
rooms, technical offices, halls, specialised stores, department stores, 
banks
Luminous emittance 1: 
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Project 1 / Luminaire parts list
20 Pieces HavellsSylvania 0058834 EQUILIBRO MPD 
2x55W A2
Article No.: 0058834
Luminous flux (Luminaire): 4301 lm
Luminous flux (Lamps): 9600 lm
Luminaire Wattage: 122.0 W
Luminaire classification according to CIE: 100
CIE flux code: 46 79 96 100 45
Fitting: 2 x LYNX-LE 55W (Correction Factor 
1.000).
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Luminaires (coordinates list)
HavellsSylvania 0058834 EQUILIBRO MPD 2x55W A2
4301 lm, 122.0 W, 1 x 2 x LYNX-LE 55W (Correction Factor 1.000).
No. Position [m] Rotation [°]
X Y Z X Y Z
1 2.000 0.750 3.600 0.0 0.0 90.0
2 2.000 2.250 3.600 0.0 0.0 90.0
3 2.000 3.750 3.600 0.0 0.0 90.0
4 2.000 5.250 3.600 0.0 0.0 90.0
5 6.000 0.750 3.600 0.0 0.0 90.0
6 6.000 2.250 3.600 0.0 0.0 90.0
7 6.000 3.750 3.600 0.0 0.0 90.0
8 6.000 5.250 3.600 0.0 0.0 90.0
9 10.000 0.750 3.600 0.0 0.0 90.0
10 10.000 2.250 3.600 0.0 0.0 90.0
11 10.000 3.750 3.600 0.0 0.0 90.0
12 10.000 5.250 3.600 0.0 0.0 90.0
13 14.000 0.750 3.600 0.0 0.0 90.0
14 14.000 2.250 3.600 0.0 0.0 90.0
15 14.000 3.750 3.600 0.0 0.0 90.0
16 14.000 5.250 3.600 0.0 0.0 90.0
17 18.000 0.750 3.600 0.0 0.0 90.0
18 18.000 2.250 3.600 0.0 0.0 90.0
19 18.000 3.750 3.600 0.0 0.0 90.0
20 18.000 5.250 3.600 0.0 0.0 90.0
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 6 / Summary
Height of Room: 3.500 m, Mounting Height: 3.611 m, Maintenance factor: 
0.80
Values in Lux, Scale 1:143
Surface  [%] Eav [lx] Emin [lx] Emax [lx] u0
Workplane / 581 384 708 0.661
Floor 63 401 84 564 0.210
Ceiling 70 239 196 346 0.820
Walls (4) 70 342 38 980 /
Workplane:
Height: 1.000 m
Grid: 128 x 32 Points 
Boundary Zone: 0.500 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.434, Ceiling / Working Plane: 0.411. 
Luminaire Parts List
Specific connected load: 20.33 W/m² = 3.50 W/m²/100 lx (Ground area: 120.00 m²) 
No. Pieces Designation (Correction Factor)  (Luminaire) [lm]  (Lamps) [lm] P [W]
1 20 HavellsSylvania 0058834 EQUILIBRO MPD 2x55W A2 (1.000) 4301 9600 122.0
Total: 86018 Total: 192000 2440.0
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Workplane / Isolines (E)
Values in Lux, Scale 1 : 143
Position of surface in room:
Working plane with 0.500 m 
Boundary Zone
Marked point:
(0.500 m, 0.500 m, 1.000 m) 
Grid: 128 x 32 Points 
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
566 374 689 0.661 0.543
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 6 / Workplane / Greyscale (E)
Scale 1 : 143
Position of surface in room:
Working plane with 0.500 m 
Boundary Zone
Marked point:
(0.500 m, 0.500 m, 1.000 m) 
Grid: 128 x 32 Points 
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
581 384 708 0.661 0.542
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Workplane / Value Chart (E)
Values in Lux, Scale 1 : 143
Not all calculated values could be displayed. 
Position of surface in room:
Working plane with 0.500 m 
Boundary Zone
Marked point:
(0.500 m, 0.500 m, 1.000 m) 
Grid: 128 x 32 Points 
Eav [lx] Emin [lx] Emax [lx] u0 Emin / Emax
566 374 689 0.661 0.543
Page 1
Project 1
23.11.2015
Operator
Telephone
Fax
e-Mail
Room 1 / Light scene 6 / Photometric Results
Total Luminous Flux: 86018 lm
Total Load: 2440.0 W
Maintenance factor: 0.80
Boundary Zone: 0.500 m
Surface Average illuminances [lx] Reflection factor [%] Average luminance [cd/m²] 
direct indirect total
Workplane 396 185 581 / / 
Floor 244 157 401 63 80
Ceiling 0.02 239 239 70 53
Wall 1 176 185 361 70 81
Wall 2 131 205 335 70 75
Wall 3 175 190 365 70 81
Wall 4 68 138 206 70 46
Uniformity on the working plane
u0: 0.661 (1:2) 
Emin / Emax: 0.542 (1:2) 
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.434, Ceiling / Working Plane: 0.411. 
Specific connected load: 20.33 W/m² = 3.50 W/m²/100 lx (Ground area: 120.00 m²) 